Item Date Code Cust Text Fail Text  

 

 

Repair Text

SC904 021 01 THIS IS THE 2ND TIME THIS UNIT HAS BEEN REJECTED-UNIT GENERATES INTERMITTENT FALSHING 7 FAULTS MONITORED FAULT OUTPUT ON J4-12 THIS SIGNAL SHOWS A LOT OF NOISE AND OSCILLATION RIDING ONTHE OUTPUT WHICH IS UNUSUAL VERIFIED THAT THE FLASHING 7
SC904 021 01
SC904-021-01

2700

Q1 THREW Q4 BLEW UP BURNT TRACES, BOARD UNREPAIRABLE. REPLACED POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

3099

Q1 THREW Q4 BLEW UP BURNT TRACES, BOARD UNRELIABLE, NON WARRANTY, NEED CUSTOMER APPROVAL MAJOR REPAIR CHARGE.
SC903NN-031-01

1301

NO ERROR CODE ON POWER UP. LED FLASHES BREIFLY EVERY 5-6 SECONDS. NORMALLY BLINKS “Z” IN THE TEST

 

 

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2900

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2100

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

3300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

2600

C96 ON CONTROL BOARD LEAKING. REPLACED C96 ON CONTROL BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

600

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

1101

RECEIVED W/ A STRIPPED SCREW J1 ON POWER BOARD DEFECTIVE. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST.

47147502

material rec’d w/out spc data, as required per qs-9000 & the letter sent by the buyer
SC903NN-031-01 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
sc904-021-01

701

pick up axis on shuttle was cycle velocity of 170 axis stop at 4.7 max volt, er NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902 028 01

900

THIS UNIT WILL NOT BE RETURNED – MACHINE STOPS W/ ERROR MESSAGE “TIMEOUT” ERROR WAITINT FOR HEAD UP” AFTER SERVO WAS REPLACED MACHINE RAN NORMALLY. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903NN 033 01

3898

DO DEBIT WILL BE TAKEN -UIC WOULD LIKE A FAILURE ANALYSIS  SENT TO GENE KUCINSKI ASAP  – UIC DOES NOT WANT THIS UNIT RETURNED. FLASHING 5 AT POWER UP, J3 WERE DEFECTIVE ON POWER BOARD AND C11 SHORTED TO GROUND ON CONTROL BOARD, NON-WARRANTY, WAITING CUSTOMER APPROVAL MINOR CHARGE.
SC903 020 01

3300

BLINKING 7 AT POWER UP. J3 WIRE ON POWER BOARD DEFECTIVE. REPLACED WIRE ON POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2000

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2100

J1 CONNECTOR DAMAGED. REPLACED CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3098

FAULT CODE 7 WHEN 240V APPLIED. R5,R6 AND R7 DEFECTIVE ON POWER BOARD. REPLACED R5,R6, AND R7. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

4000

HAS A BLINKING FAULT CODE UC . THIS AMP WAS REJECTED PREVIOUSLY ON 10-13-00.  QN#200027394. THE REASON FOR THE REJECT WAS NO LED, DIGITAL OUTPUTS INCORRECT PROGRAM WAS NOT DOWN LOADED FOR CUSTOMER. DOWN LOADED PROGRAM. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

3400

RECEIVED MISSING COVER BETWEEN SYSTEM STATUS DISPLAY AND J4 MISSING FACE PANEL. PUT FACE PANEL.
SC902-028-01

700

HEAD TOOLING CANNOT FINISHING ZERO.  UNIT CAME BACK FROM CUSTOMER RA#60018965 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-032-01

5200

MISSING COVER AT EXPANSION SLOT Unit  okay UNIT MISSING PANEL. INSTALLED PANEL. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

3599

SERVO CAUSED THE INERTION TOOLING TO VIBRATE IN STATIC MODE DEDC NOISE PROBLEM ON CONTROL BOARD-UNREPAIRABLE DEFECTIVE C65 ON POWER BOARD. REPLACED DEFECTIVE PARTS. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

1100

REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO). NO PROBLEM FOUND. RECALIBRATED THE UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

1100

REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO). NO PROBLEM FOUND. RECALIBRATED THE UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 IN AMC SOFTWARE X AXIS AMP WOULD NOT STAY INABLED TO DRIVE THE X AXIS
SC903-027-01

2497

defective u3 on power board. replaced u3. unit passed burn-in and final test. minor non-warranty – PLEASE APPROVE CHARGES – THANK YOU!KIM
SC904-021-01

9603

DEFECTIVE QM1 MODULE, SHORTED.NEED CUSTOMER APPROVAL FOR MINOR REPAIR PLEASE ADVISE – THANK YOU! KIM
SC904-021-01

1900

SETTLE TIME LIMIT ERROR IN TEST UNIT HAS OVER VOLTAGES FAULT, POWER BOARD BLEW UP DURING TROUBLESHOUTING, NEEDS TO REPLACED A NEW BOARD. REPLACED A NEW POWER BOARD.UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

1900

SETTLE TIME LIMIT ERROR  IN TEST
SC904-021-01

3000

Y1 AXIS AMP DROPS OUTDURING COMPNENT RUN-  FLASHIN 7 ON AMP UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC902-028-01

1499

FIELD FAILURE. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

4298

NEED UPGRADE TO V1.6 FIRMWARE FOUND DAMAGED FLEX CABLE. UPGRADED TO V1.6 FIRMWARE.DAMAGED FLEX CABLE WAS REPLACED,NON WARRANTY CHARGE.
SC903-020-01

3400

GAVE POSITION FOLLOWING ERROR SWAPPED AMP CORRECTED PROBLEM. TRYED ON ANOTHER MACHINE, SAME PROBLEM. UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01

3400

THEY ORDERED SC903-020-01, BUT REC’D THE SC902 INSTEAD. issue credit.Order was entered correctly.Wrong item was packed and shipped SHIPPING/INSPECTION  ERROR,CUSTOMER ORDERED SC903-020-01 WE SHIPPED SC902 REPLACED WITH CORRECT MODEL AS SC903-020-01
SC903NN-033-01

598

Z-SPAN CAN’T MOVE UNIT WORKS OK.PASSED BURN IN & FINAL TEST. UPGRADE TO V1.6 FIRMWARE FIRMWARE UPGRADED TO V1.6.NO PROBLEM FOUND
SC904-021-01

3000

Y-1 AXIS WOULD NOT INITIATE BAD AMP UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC904-021-01

2800

BAD SCREW IN J1-5 AS RECEIVED JI PIN 6 DAMAGED.CUSTOMER MIGHT USE ELECTRIC SCREWDRIVER AS SET OVER TORQUE,CAUSED DAMAGE. REPLACED J1 PIN 5&6 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2900

AFTER DRY CYCLING FOR 48HRS, AMP ERRORED OUT WITH A BLINKIN E2 R114 NTC ON THE POWER BOARD OPEN,BROKEN LEAD FROM INSIDE THE LUG. REPLACED R114.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2700

MISSING JACKSCREWS ON J4 INTERFACE CONNECTOR MISSING JACK SCREW ON J4 CONNECTOR INSTALLED JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST.
sc904-021-01

2800

BROKEN JACKSCREW ON J4 INTERFACE CONNECTOR JACK SCREW ON J4 CONNECTOR BROKEN REPLACED A NEW JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2700

J1-4 DOES NOT TIGHTEN WIRE CONNECTION. IT APPEARS LIKE THERE IS NO LOCKING GATE IN TERMINAL J1 PIN 4 DAMAGED FROM POWER BOARD REPLACED J1 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

1700

CONTROL BOARD HAS NOISE PROBLEM.UNABLE TO DUPLICATE THE CAUSE , NEED TO REPLACED CONTROL BOARD REPLACED CONTROL BOARD.PASSED BURN IN & FINAL TEST
SC903-020-01

800

RESOLVER FEEDBACK IS HIGH CURRENT COMMOND FEEDBACK IS AT 1/2 VOLTS PEAK TO PEAK NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-021-01 FLASHING F3 (PARAMETER MEMORY ERROR
SC904-021-01

1600

J1 CONNECTOR PIN 6 TERMINAL IS BROKEN. tHE BOX HAS A HOLE IN IT IN THE SAME AREA OF THE DAMAGE
SC904-021-01

2700

Q1 THREW Q4 BLEW UP BURNT TRACES, BOARD UNREPAIRABLE. REPLACED POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

3099

Q1 THREW Q4 BLEW UP BURNT TRACES, BOARD UNRELIABLE, NON WARRANTY, NEED CUSTOMER APPROVAL MAJOR REPAIR CHARGE.
SC903NN-031-01

1301

NO ERROR CODE ON POWER UP. LED FLASHES BREIFLY EVERY 5-6 SECONDS. NORMALLY BLINKS “Z” IN THE TEST NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2900

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2100

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

3300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

2600

C96 ON CONTROL BOARD LEAKING. REPLACED C96 ON CONTROL BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

600

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

1101

RECEIVED W/ A STRIPPED SCREW J1 ON POWER BOARD DEFECTIVE. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST.

47147502

material rec’d w/out spc data, as required per qs-9000 & the letter sent by the buyer
SC903NN-031-01 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
sc904-021-01

701

pick up axis on shuttle was cycle velocity of 170 axis stop at 4.7 max volt, er NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902 028 01

900

THIS UNIT WILL NOT BE RETURNED – MACHINE STOPS W/ ERROR MESSAGE “TIMEOUT” ERROR WAITINT FOR HEAD UP” AFTER SERVO WAS REPLACED MACHINE RAN NORMALLY. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903NN 033 01

3898

DO DEBIT WILL BE TAKEN -UIC WOULD LIKE A FAILURE ANALYSIS  SENT TO GENE KUCINSKI ASAP  – UIC DOES NOT WANT THIS UNIT RETURNED. FLASHING 5 AT POWER UP, J3 WERE DEFECTIVE ON POWER BOARD AND C11 SHORTED TO GROUND ON CONTROL BOARD, NON-WARRANTY, WAITING CUSTOMER APPROVAL MINOR CHARGE.
SC903 020 01

3300

BLINKING 7 AT POWER UP. J3 WIRE ON POWER BOARD DEFECTIVE. REPLACED WIRE ON POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2000

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2100

J1 CONNECTOR DAMAGED. REPLACED CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3098

FAULT CODE 7 WHEN 240V APPLIED. R5,R6 AND R7 DEFECTIVE ON POWER BOARD. REPLACED R5,R6, AND R7. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

4000

HAS A BLINKING FAULT CODE UC . THIS AMP WAS REJECTED PREVIOUSLY ON 10-13-00.  QN#200027394. THE REASON FOR THE REJECT WAS NO LED, DIGITAL OUTPUTS INCORRECT PROGRAM WAS NOT DOWN LOADED FOR CUSTOMER. DOWN LOADED PROGRAM. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

3400

RECEIVED MISSING COVER BETWEEN SYSTEM STATUS DISPLAY AND J4 MISSING FACE PANEL. PUT FACE PANEL.
SC902-028-01

700

HEAD TOOLING CANNOT FINISHING ZERO.  UNIT CAME BACK FROM CUSTOMER RA#60018965 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-032-01

5200

MISSING COVER AT EXPANSION SLOT Unit  okay UNIT MISSING PANEL. INSTALLED PANEL. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

3599

SERVO CAUSED THE INERTION TOOLING TO VIBRATE IN STATIC MODE DEDC NOISE PROBLEM ON CONTROL BOARD-UNREPAIRABLE DEFECTIVE C65 ON POWER BOARD. REPLACED DEFECTIVE PARTS. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

1100

REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO). NO PROBLEM FOUND. RECALIBRATED THE UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

1100

REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO). NO PROBLEM FOUND. RECALIBRATED THE UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 IN AMC SOFTWARE X AXIS AMP WOULD NOT STAY INABLED TO DRIVE THE X AXIS
SC903-027-01

2497

defective u3 on power board. replaced u3. unit passed burn-in and final test. minor non-warranty – PLEASE APPROVE CHARGES – THANK YOU!KIM
SC904-021-01

9603

DEFECTIVE QM1 MODULE, SHORTED.NEED CUSTOMER APPROVAL FOR MINOR REPAIR PLEASE ADVISE – THANK YOU! KIM
SC904-021-01

1900

SETTLE TIME LIMIT ERROR IN TEST UNIT HAS OVER VOLTAGES FAULT, POWER BOARD BLEW UP DURING TROUBLESHOUTING, NEEDS TO REPLACED A NEW BOARD. REPLACED A NEW POWER BOARD.UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

1900

SETTLE TIME LIMIT ERROR  IN TEST
SC904-021-01

3000

Y1 AXIS AMP DROPS OUTDURING COMPNENT RUN-  FLASHIN 7 ON AMP UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC902-028-01

1499

FIELD FAILURE. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01

4298

NEED UPGRADE TO V1.6 FIRMWARE FOUND DAMAGED FLEX CABLE. UPGRADED TO V1.6 FIRMWARE.DAMAGED FLEX CABLE WAS REPLACED,NON WARRANTY CHARGE.
SC903-020-01

3400

GAVE POSITION FOLLOWING ERROR SWAPPED AMP CORRECTED PROBLEM. TRYED ON ANOTHER MACHINE, SAME PROBLEM. UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01

3400

THEY ORDERED SC903-020-01, BUT REC’D THE SC902 INSTEAD. issue credit.Order was entered correctly.Wrong item was packed and shipped SHIPPING/INSPECTION  ERROR,CUSTOMER ORDERED SC903-020-01 WE SHIPPED SC902 REPLACED WITH CORRECT MODEL AS SC903-020-01
SC903NN-033-01

598

Z-SPAN CAN’T MOVE UNIT WORKS OK.PASSED BURN IN & FINAL TEST. UPGRADE TO V1.6 FIRMWARE FIRMWARE UPGRADED TO V1.6.NO PROBLEM FOUND
SC904-021-01

3000

Y-1 AXIS WOULD NOT INITIATE BAD AMP UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC904-021-01

2800

BAD SCREW IN J1-5 AS RECEIVED JI PIN 6 DAMAGED.CUSTOMER MIGHT USE ELECTRIC SCREWDRIVER AS SET OVER TORQUE,CAUSED DAMAGE. REPLACED J1 PIN 5&6 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2900

AFTER DRY CYCLING FOR 48HRS, AMP ERRORED OUT WITH A BLINKIN E2 R114 NTC ON THE POWER BOARD OPEN,BROKEN LEAD FROM INSIDE THE LUG. REPLACED R114.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2700

MISSING JACKSCREWS ON J4 INTERFACE CONNECTOR MISSING JACK SCREW ON J4 CONNECTOR INSTALLED JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST.
sc904-021-01

2800

BROKEN JACKSCREW ON J4 INTERFACE CONNECTOR JACK SCREW ON J4 CONNECTOR BROKEN REPLACED A NEW JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

2700

J1-4 DOES NOT TIGHTEN WIRE CONNECTION. IT APPEARS LIKE THERE IS NO LOCKING GATE IN TERMINAL J1 PIN 4 DAMAGED FROM POWER BOARD REPLACED J1 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01

1700

CONTROL BOARD HAS NOISE PROBLEM.UNABLE TO DUPLICATE THE CAUSE , NEED TO REPLACED CONTROL BOARD REPLACED CONTROL BOARD.PASSED BURN IN & FINAL TEST
SC903-020-01

800

RESOLVER FEEDBACK IS HIGH CURRENT COMMOND FEEDBACK IS AT 1/2 VOLTS PEAK TO PEAK NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-021-01 FLASHING F3 (PARAMETER MEMORY ERROR
SC904-021-01

1600

J1 CONNECTOR PIN 6 TERMINAL IS BROKEN. tHE BOX HAS A HOLE IN IT IN THE SAME AREA OF THE DAMAGE
SC904 021 01

1101

RECEIVED W/ A STRIPPED SCREW

47147502

material rec’d w/out spc data, as required per qs-9000 & the letter sent by the buyer
SC903NN-031-01 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
sc904-021-01

701

pick up axis on shuttle was cycle velocity of 170 axis stop at 4.7 max volt, er NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902 028 01

900

THIS UNIT WILL NOT BE RETURNED – MACHINE STOPS W/ ERROR MESSAGE “TIMEOUT” ERROR WAITINT FOR HEAD UP” AFTER SERVO WAS REPLACED MACHINE RAN NORMALLY. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3300

OUTPUT OVER CURRENT, BLINKING 7 , WOULD NOT RESET CODE 7,U13 DEFECTIVE ON POWER BOARD. REPLACEDU 13. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

601

Y2 AMP HAS FLASHING 7, AMP WILL BECOME ENABLED FOR NO APPARENT REASON C50 ON CONTROL BOARD DEFECTIVE. REPLACED C50. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

100

FLASHING FAULT CODE 5 WHEN 230V APPLIED C11 LEAKING ON CONTROL BOARD. REPLACED C11 ON CONTROL BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC903NN 033 01

3898

DO DEBIT WILL BE TAKEN -UIC WOULD LIKE A FAILURE ANALYSIS  SENT TO GENE KUCINSKI ASAP  – UIC DOES NOT WANT THIS UNIT RETURNED. FLASHING 5 AT POWER UP, J3 WERE DEFECTIVE ON POWER BOARD AND C11 SHORTED TO GROUND ON CONTROL BOARD, NON-WARRANTY, WAITING CUSTOMER APPROVAL MINOR CHARGE.
SC903 020 01

3300

BLINKING 7 AT POWER UP. J3 WIRE ON POWER BOARD DEFECTIVE. REPLACED WIRE ON POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2000

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2100

J1 CONNECTOR DAMAGED. REPLACED CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

300

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3098

FAULT CODE 7 WHEN 240V APPLIED. R5,R6 AND R7 DEFECTIVE ON POWER BOARD. REPLACED R5,R6, AND R7. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

4000

HAS A BLINKING FAULT CODE UC . THIS AMP WAS REJECTED PREVIOUSLY ON 10-13-00.  QN#200027394. THE REASON FOR THE REJECT WAS NO LED, DIGITAL OUTPUTS INCORRECT PROGRAM WAS NOT DOWN LOADED FOR CUSTOMER. DOWN LOADED PROGRAM. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3100

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3100

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

2800

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

3100

NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903 020 01

301

MAKES EXCESSIVE NOISE WHEN CYCLING X AXIS NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

3400

RECEIVED MISSING COVER BETWEEN SYSTEM STATUS DISPLAY AND J4 MISSING FACE PANEL. PUT FACE PANEL.
SC902 028 01

3800

UNIT COMES UP W/ ERROR CODE F3 NO PROBLM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01

5100

FAULTOUT ATTEMPTION TO ZERO MACHINE, INTERMITTENT FLASHING 7 ON MACHINE R047 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904 021 01

5100

FAILS GENERAL PURPOSE DIGITAL INPUTS TEST AMP DISPLAYS FLASHING 7 ERROR
SC904-032-01 DAMAGED AT UIC ON MFG FLOOR (BENT PIN)
SC902 028 01 0700 HEAD TOOLING CANNOT FINISHING ZERO.  UNIT CAME BACK FROM CUSTOMER RA#60018965
SC904-032-01 5200 MISSING COVER AT EXPANSION SLOT Unit  okay
SC902-028-01 1100 REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO).
SC902-028-01 1100 REPORT FROM CUSTOMER IS THAT UNITS (HEAD AXIS WOULD NOT ZERO).
SC902-028-01 3599 SERVO CAUSED THE INERTION TOOLING TO VIBRATE IN STATIC MODE DEDC NOISE PROBLEM ON CONTROL BOARD-UNREPAIRABLE DEFECTIVE C65 ON POWER BOARD. REPLACED DEFECTIVE PARTS. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 IN AMC SOFTWARE X AXIS AMP WOULD NOT STAY INABLED TO DRIVE THE X AXIS
SC904-021-01 4800 FLASHING “E” ON AMPLIFIER DEFECTIVE CONTROL BOARD. REPLACED CONTROL BOARD,UNIT PASSED BURN IN & FINAL TEST
SC903 020 01 4500 AMC POSITION FOLLOWING ERROR IN X2 AXIS WOULD NOT DRIVE AXIS, FLASHING E7 UNIT WORKS OK,UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC904-021-01 4300 FLASHING 22 ON AMP. Y1 WON’T ENABLE UNIT WORKS OK,UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 4600 POSITION FOLLOWING ERROR UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 4799 DEFECTIVE POWER BOARD, OPEN BETWEEN Q18 AND Q23. REPLACED POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 2100 F1 FUSE BLOWN BR2 SHORTED. REPLACED DEFECTIVE PARTS.UNIT PASSED BURN IN & FINAL TEST
SC903-020-01 2100 UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 2299 UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-027-01 2497 defective u3 on power board. replaced u3. unit passed burn-in and final test.
SC904-021-01 9603 DEFECTIVE QM1 MODULE, SHORTED.NEED CUSTOMER APPROVAL FOR MINOR REPAIR
SC904-021-01 4598 RESISTORS OUT OF TOLERANCE (2) REPLACED R206 & 256.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 0100 C35 ON POWER BOARD DEFECTIVE,CUSTOMER DAMAGED J1 PIN 1 ON CONNECTOR OVER TORQUE BY CUSTOMER RELACED J1 CONNECTOR AND C35.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 4999 CUSTOMER DAMAGED J1 PIN 1 CONNECTOR,CAUSED BY OVER TORQUE. REPLACED J1 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 4199 UNIT WORKS OK.UNIT PASSED BURNIN & FINAL TEST NO PROBLEM FOUND
SC904-021-01 4000 NO LED.  DIGITAL OUTPUTS INCORRECT. UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 4799 UNKNOWN UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 3600 NOT ENOUGH POWER TO RUN MOTOR AT FULL SPEED. POWER BOARD BURNED NEAR J1,M4 & R73 REPLACED POWER BOARD,UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 1900 SETTLE TIME LIMIT ERROR IN TEST UNIT HAS OVER VOLTAGES FAULT, POWER BOARD BLEW UP DURING TROUBLESHOUTING, NEEDS TO REPLACED A NEW BOARD. REPLACED A NEW POWER BOARD.UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1900 SETTLE TIME LIMIT ERROR  IN TEST
SC903-020-01 3500 LOOSE COMPONENT RATTLING AROUNDIN CASE AS RECEIVED THERE WAS A LOOSE SCREW CAME OFF FROM POWER BOARD. REMOVED A LOOSE SCREW; RE-INSTALLED/CHECK ALL SCREWS IN A UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 2600 FIELD FAILURES. THESE ARE TO BE ANALYZED ONLY. CUST DOES NOT WANT UNITS BACK. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 4799 FIELD FAILURES. THESE ARE TO BE ANALYZED ONLY. CUST DOES NOT WANT UNITS BACK. BURNT TRANSISTORS Q1 Q2,Q3,Q4, ALSO SHORTED C303,C40 ON POWER BOARD.
SC904-021-01 1799 FIELD FAILURES. THESE ARE TO BE ANALYZED ONLY. CUST DOES NOT WANT UNITS BACK. C29 SHORTED; Q1 TO Q4 BLOWN ON POWER BOARD.
SC904-021-01 9636 FIELD FAILURES. THESE ARE TO BE ANALYZED ONLY. CUST DOES NOT WANT UNITS BACK. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 2500 FIELD FAILURES. THESE ARE TO BE ANALYZED ONLY. CUST DOES NOT WANT UNITS BACK. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 3000 Y1 AXIS AMP DROPS OUTDURING COMPNENT RUN-  FLASHIN 7 ON AMP UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903NN-033-01 3999 Z AXIS CAN’T BE ZEROED. UNIT WORKS OK .BURN IN & FINAL TEST NO PROBLEM FOUND.UPGRADED TO FIRMWARE V1.6 PASSED BURN IN & FINAL TEST
SC902-028-01 3798 Z-SPZN AXIS CAN’T ZERO. UNIT WORKS OK. FIRMWARE UPGRADE TO V1.6.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
sc902-028-01 4399 M/C CAN’T ZERO. UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC902-028-01 1499 FIELD FAILURE. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 3400 GAVE POSITION FOLLOWING ERROR SWAPPED AMP CORRECTED PROBLEM. TRYED ON ANOTHER MACHINE, SAME PROBLEM. UNIT WORKS OK.PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC903-020-01 3400 THEY ORDERED SC903-020-01, BUT REC’D THE SC902 INSTEAD. issue credit.Order was entered correctly.Wrong item was packed and shipped SHIPPING/INSPECTION  ERROR,CUSTOMER ORDERED SC903-020-01 WE SHIPPED SC902 REPLACED WITH CORRECT MODEL AS SC903-020-01
sc904-021-01 3400 Y AMP WOULD NOT OPERATE AND J1-1 BLOCK IS BROKEN AS RECEIVED DAMAGED J1 -1,INTERMITTENT PROBLEM CODE 7. REPLACED J1 -1, J2 -1,INTERMITTENT PROBLEM ON CONTROL BOARD.UNIT PASSED BURN IN & FINAL TEST
SC902-028-01 4599 FIELD FAILURE. SWITCHING OFF AXIS HEAD CHAIN/MOTOR DRIVE DURING LONG CHAINS TRAVELS WITH NOMINAL SPEED. UPGRADED TO V1.6 FIRMWARE.UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND  RETURN TO CUSTOMER
SC902-028-01 4298 NEED UPGRADE TO V1.6 FIRMWARE FOUND DAMAGED FLEX CABLE. UPGRADED TO V1.6 FIRMWARE.DAMAGED FLEX CABLE WAS REPLACED,NON WARRANTY CHARGE.
SC903NN-033-01 0598 Z-SPAN CAN’T MOVE UNIT WORKS OK.PASSED BURN IN & FINAL TEST. UPGRADE TO V1.6 FIRMWARE FIRMWARE UPGRADED TO V1.6.NO PROBLEM FOUND
SC903NN-033-01 4398 Z-SPAN AXIS CAN’T ZERO.   NO DEBIT TAKEN DO FAILURE ANALYSIS AND SEND REPORT TO gENE kUCINSKI FIRMWARE UPGRADE TO 1.6.UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST UPGRADED TO V1.6.NO PROBLEM FOUND
SC904-021-01 2700 STRIPPED OUT SCREW IN J2 (MOTOR) PLUG LOC. 3 J2, PIN 3 DAMAGED.CUSTOMER MIGHT OVER TIE CAUSED DAMAGE J2 CONNECTOR. REPLACED J2 CONNECTOR,UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 2900 WHILE IN AMC, Y AND Z AXIS WOULD NOT ZERO. ALSO FOUND Y AND Z AMP J2 SLOT 4 WAS DAMAGED J2 4 ON PUR DAMAGED POSSIBLE OVER TORQUE,CAUSED BY CUSTOMER REPLACED J2 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 2800 BAD SCREW IN J1-5 AS RECEIVED JI PIN 6 DAMAGED.CUSTOMER MIGHT USE ELECTRIC SCREWDRIVER AS SET OVER TORQUE,CAUSED DAMAGE. REPLACED J1 PIN 5&6 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 3000 Y-1 AXIS WOULD NOT INITIATE BAD AMP UNIT WORKS OK.UNIT PASSED BURN IN & FINAL TEST NO PROBLEM FOUND
SC904-021-01 2900 AFTER DRY CYCLING FOR 48HRS, AMP ERRORED OUT WITH A BLINKIN E2 R114 NTC ON THE POWER BOARD OPEN,BROKEN LEAD FROM INSIDE THE LUG. REPLACED R114.UNIT PASSED BURN IN & FINAL TEST
sc904-032-01 2800 J1-6 BROKE, SYMPTOM: FLASHING “7” AMP J1 PIN 6 DAMAGED,U2 ON POWER BOARD DEFECTIVE REPLACED J1 PIN 5&6,UN ON POWER BOARD.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 2800 NO DEBIT TAKEN    Y1 AMP  J1-5 BROKEN WHEN TRIED TO TIGHTEN CUSTOMER OVERTIED J1 CONNECTOR, CAUSED PINS 1& 5 DAMAGE REPLACED J1 CONNECTOR UNIT PASSED BURN IN & FINAL TEST
sc904-021-01 2800 BROKEN JACKSCREW ON J4 INTERFACE CONNECTOR JACK SCREW ON J4 CONNECTOR BROKEN REPLACED A NEW JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 2700 MISSING JACKSCREWS ON J4 INTERFACE CONNECTOR MISSING JACK SCREW ON J4 CONNECTOR INSTALLED JACK SCREW TO J4.UNIT PASSED BURN IN & FINAL TEST.
SC904-021-01 2700 J1-4 DOES NOT TIGHTEN WIRE CONNECTION. IT APPEARS LIKE THERE IS NO LOCKING GATE IN TERMINAL J1 PIN 4 DAMAGED FROM POWER BOARD REPLACED J1 CONNECTOR.UNIT PASSED BURN IN & FINAL TEST
SC904-021-01 1700 CONTROL BOARD HAS NOISE PROBLEM.UNABLE TO DUPLICATE THE CAUSE , NEED TO REPLACED CONTROL BOARD REPLACED CONTROL BOARD.PASSED BURN IN & FINAL TEST
SC904-021-01 1900 AMP NULL NOT WORKING UNIT WORKS OK.  UNIT PASSED BURN-IN AND FINAL TEST. NO REPAIR WAS NEEDED.
SC904-021-01 2500 CONNECTOR J1 TOP END COVER FELL OFF WHEN TERMINATING TO J1-6. tHEN SCREW CAME OUT OF J1-6 J1 PINS 5&6 STRIPPED OFF. CUSTOMER MIGHT USE ELECTRIC SCREW DRIVER TO TIE DOWN CONNECTOR, CAUSED IT DAMAGED. REPLACED J1 CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 2700 J1-5 TERMINAL CONNECTION COULD NOT BE MADE, THEN CONN J1 SPLIT BETWEEN TERMS 5 AND 6 J1 PINS 5&6 STRIPPED OFF. CUSTOMER MIGHT USE ELECTRIC SCREW DRIVER TO TIE DOWN CONNECTOR, CAUSED IT DAMAGED. REPLACED J1 CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 1200 MISSING HARDWARE. MISSING STANDOFFON J4 PLUG T2 DEFECTIVE ON POWER BOARD. REPLACED T2 AND ADDED STAND OFF. UNIT PASSED BURN IN AND FINAL TEST.
SC902-028-01 2600 ORDERED SC902-028-01 ON SO# 597454. WE SHIPPED THIS SC903-020-01. PLEASE REPLACE WITH CORRECT UNIT. WE SENT OUT A CORRECT UNIT AS A SC902-028-01. BUT WRONG LABEL WAS INSTALLED TO A UNIT. RE-LABELED A UNIT WITH CUSTOMER PART #46878701 (SC902-028-01). UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 2100 POSITION FOLLOWING ERRROR. NO OUTPUT FROM AMP PER SCOTT LADD MOTOR WILL NOT RUN DUE TO AN OPEN TRACE OF TSV OF U9 ON THE CONTROL BOARD. ADDED A JUMPER. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 2400 LOOSE HARDWARE INTERNALLY 3 MISSING SCREWS W/C WERE FLOATING UNDERNEATH THE POWER BOARD. REINSTALLED THE POWER BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 2300 COULDN’T INSTALL WIRE TERMINATION IN J2-4 AND TERMINAL J2-4 NOW OUT OF LINE WITH J2 -1,2,3 (SNAPPED LOOSE FROM TEMINAL BLOCK) J2 PIN 4 WAS BROKEN ON POWER BOARD. REPLACED J2. UNIT PASSED BURN IN AND FINAL TEST.
SC903NN-031-01 2300 MISSING STANDOFF ON J4 CONNECTOR, RECEIVED THIS WAY MISSING STANDOFF. ADDED STANDOFF. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 1700 BILL VANCOTT UNIT NO LONGER FUNCTIONS PROPERLY.  BVC UIC FAULT.   NO DEBIT WAS TAKEN NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST
SC903NN-031-01 2200 STANDOFF IS TO SHORT ON CONNECTOR J4. WRONG COMPONENT STANDOFF DID NOT HAVE THE SAME LENGTH ON J4 CONNECTOR. REPLACED STANDOFF. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1900 CONFIGURATION OF AMP FILMWARE NOT UIC PER SCOTT LADD NO PROBLEM FOUND UNIT PASSED BURN-IN AND FINAL TEST
SC903-020-01 0800 RESOLVER FEEDBACK IS HIGH CURRENT COMMOND FEEDBACK IS AT 1/2 VOLTS PEAK TO PEAK NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1600 3,J1 CONNECTOR END CAB IS LOOSE IN BOX HAS FALLEN OFF J1, CONNECTOR STRIP BOX HAS DAMAGE TOO. JI PIN 6 WAS BROKEN ON POWER BOARD REPLACED JI PIN 6. UNIT PASSED BURN-IN AND FINAL TEST
SC904-021-01 1900 FLASHING A BUS OVER VOLTAGE NO PROBLEM FOUND UNIT PASSED BURN-IN AND FINAL TEST
SC904-021-01 1700 F-3 ERROR MEMORY ERROR ON CONTROL BOARD REDOWNLOAD PROGRAM PARAMETERS. UNIT PASSED BURN-IN AND FINAL TEST
SC902-028-01 1200 ARF1 PROGRAMEDFOR 1HZ. ARFO PROGRAMED FOR 400 MH INSTEAD OF 500 MH. UNITS CHECKED BY ELECTRICAL ENG, STUART JOHNSON NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 1200 ARF1 PROGRAMEDFOR 1HZ. ARFO PROGRAMED FOR 400 MH INSTEAD OF 500 MH. UNITS CHECKED BY ELECTRICAL ENG, STUART JOHNSON NO PROBLEM FOUND UNIT PASSED BURN-IN AND FINAL TEST
SC904-021-01 1700 J1-5 WILL NOT ACCEPT WIRE TERMINAL NOR LOOSEN OR TIGHTEN. J1 PIN 5 WAS BROKEN ON POWER BOARD. REPLACED J1 PIN 5. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0800 MISSING COVER PLATE AND CONNECTOR J2MOTOR IS BROKEN J2 PIN 4 WAS BROKEN ON POWER BOARD. REPLACED J2. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1600 CONNECTOR J1 PIN 5 BROKEN J1 PIN 5 BROKEN ON POWER BOARD. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1400 J1-6 CANNOT INSERT TERMINAL OR LOOSEN OR TIGHTEN AS RECEIVED J1 BROKEN ON POWER BOARD. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST
SC903-021-01 FLASHING F3 (PARAMETER MEMORY ERROR
SC903-020-01 1400 FLASHING F3 (PARAMETER MEMORY ERROR) PROBLEM WAS CORRUPTED ON MEMORY CHIP. RE-DOWNLOAD, UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 1600 J1 CONNECTOR PIN 6 TERMINAL IS BROKEN. tHE BOX HAS A HOLE IN IT IN THE SAME AREA OF THE DAMAGE
SC904-001-01 1300 THIS IS THE 2ND ONE IN TWO DAYS WITH THIS PROBLEM. CARD ACCESS DOOR CANNOT BE FASTENED. WOULD LIKE ANSWER AS TO WHY ANDWHAT WILL BE DONE TO MAKE SURE THIS WILL NOT HAPPEN IN THE FUTURE CUSTOMER ISSUE: DAMAGE ON THE PANEL. HAND TIGHTEN ONLY TO AVOID THIS PROBLEM. DO NOT USE TOOLS TO TIGHTEN THE PANEL. REPLACED PANEL. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-001-01 1200 CARD ACCESS DOOR CAN NOT BE FASTENED. WHEN THEY OPENED THE BOX, THE DOOR WAS ASKEW. TRIED TO GET DOOR TO SCREW IN BUT COULDN’T DEFECTIVE SCREWS ON THE PANEL. REPLACED PANEL. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 0300 POWER ACCIDENTLY APPLIED TO ENCODER OUTPUT CUSTOMER ISSUE: U21 WAS DAMAGED ON CONTROL BOARD DUE TO WRONG POWER APPLIED ON ENCODER, WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR. REPLACED U21 ON CONTROL BOARD. UNIT PASSED BURN-IN AND FINAL TEST. MINOR NON-WARRANTY.
SC903-020-01 3297 NO INFO PROVIDED LED WAS SHOWING “-” AT POWER UP, U2 WAS EXTREMELY HOT. WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR.
SC903-020-01 4399 NO FAILURE INFO PROVIDED NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 1100 WOULD NOT ZERO ON TEST. NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0600 SCREW AT J1-6 WILL NOT TIGHTEN DOWN TO HOLD IN THE WIRE. J1 PIN 6 WAS BROKEN ON POWER BOARD. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4999 MISSING COVER ON AMP NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 0500 ENCODER EMULATOR OUTPUT MALFUNCTION. NO OUTPUT ON J4-16, J4-17, J4-14,J4-15 INTERMITTENTLY GENERATES IN PHASE RANDOM PULSE TRAINS WITH NO CHANGE IN RESOVER INPUT 8249 CUSTOMER ISSUE:U21 WAS DAMAGED DUE TO MISWIRE BY CUSTOMER, WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR. REPLACED U21. UNIT PASSED BURN-IN AND FINAL TEST. MINOR NON-WARRANTY.
SC904-021-01 4299 LOOSE CONNECTOR [J1] ON POWER BOARD. APPLIED GLUE ON CONNECTORS. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 9625 FIELD FAILURE. NO DEBIT TAKEN CUSTOMER ISSUE: OUTPUT STAGE TRANSISTOR WAS CUT. THIS CAUSED A SHORT ON OUTPUT STAGE, WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR. REPLACED OUTPUT STAGE. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 2999 FIELD FAILURE. NO DEBIT TAKEN R181 DEFECTIVE ON CONTROL BOARD. REPLACED R181. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4999 U48 PIN 4 NOT SOLDER ON CONTROL BOARD. RE-SOLDERED U48 PIN 4. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 1197 Q23 DEFECTIVE ON POWER BOARD. NEEDS CUSTOMER APPROVAL FOR MINOR REPAIR CHARGE. REPLACED Q23. UNIT PASSED BURN-IN AND FINAL TEST. MINOR NON-WARRANTY.
SC903-020-01 0800 WHEN AMP ENABLED, YOU CAN HEAR A SHORT SIZZLING AWAY. NO PROBLEM FOUND.        PLEASE FAX A COPY OF YOUR DEBIT MEMO REPORT TO BECKY 815-226-3148 UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 0600 AXIS WOULD ENABLE (8) BUT WOULD NOT DRIVE AMPS. U13 DEFECTIVE ON POWER BOARD.            PLEASE FAX COPY OF DEBIT MEMO REPORT TO BECKY REPLACED U13. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0700 CONNECTOR #5 SCREW TIGHTENED TO THE BOTTOM AND SCREW HEAD DAMAGED. TECH COULD NOT LOOSEN TO INSTALL WIRING, PLASTIC HOUSING BENT SIDEWAYS. SUSPECT MFG PROCESS ERROR AT PACSCI AS AMP WAS THIS WAY OUT OF BOX. J1 PIN 5,6 WERE BROKEN ON POWER BOARD. REPLACED J1. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0800 BROKEN TERMINAL ON BLOCK #4 J2 PIN 4 WAS BROKEN ON POWER BOARD. REPLACED J2 . UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0600 BROKEN TERMINAL ON BLOCK #3 J2 PIN 3 WAS STUCK ON POWER BOARD. REPLACED J2. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0800 J1 BAD HARDWARE J1 CONNECTOR WAS BROKEN ON POWER BOARD. REPLACED J1 CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 3599 KVP DO NOT MATCH CORRECT PROGRAM PARAMETERS. aLSO SUSPECT PERSONALITY MODULE NAD OTHER PROBLEMS NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4398 2ND FAILURE. SEE RMA 122162 FOR FIRST FAIL. INFO. CAME BACK WITH LOOSE HARDWARE INSIDE CUSTOMER ISSUE:PREVIOUS RMA CUSTOMER WANTS UNIT TO RETURN UNREPAIR. CUSTOMER APPLIED EXCESSIVE REGEN CAUSED REGEN TO MELT AND F1,F2 TO OPEN. WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR.  UNIVERSAL, PLEASE MAKE SURE YOU FAX A DEBIT MEMO REP PLEASE APPROVE THE REPAIR CHARGES OF $397.00  PLEASE ADVISE REPAIR OR RETURN! !
SC904-021-01 0200 FAILED HYPOT TEST AFTER BEING INSTALLED IN SHUTTLE LOOSE SCREWS ON MODULE OF POWER BOARD. J1 AND J2 POWER BOARD CONNECTORS WERE VERY TIGHT. U17 PIN 10 SHORTED ON CONTROL BOARD. TIGHTEN ALL LOOSE SCREWS, REPLACED J1,J2 CONNECTORS AND U17. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0300 CONN J1-1 BROKEN. I CANNOT INSERT TERMINAL TO TIGHTEN OR LOOSEN BROKEN J1-1 CONNECTOR ON POWER BOARD. REPLACED J1 CONNECTOR. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4999 LOOSE SCREWS IN ENCLOSURE AS RECEIVED POWER BOARD HAS LOOSE SCREWS [NOT COMPLETELY INSTALLED]. RE-INSTALLED ALL SCREWS FROM A UNIT. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 4899 RECEIVED BOX RE-TAPED AND NO PAPERWORK INSIDE BOX.  YOU CAN HEAR LOOSE HARDWARE INSIDE UNIT TOO. J2 BROKEN ON POWER BOARD. REPLACED J2. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0100 BAD AMP FLASHING 7 U5 DEFECTIVE ON POWER BOARD. REPLACED U5. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 0100 EZ ERROR CODE WOULDN’T AZERO   Y AXIS FLASHING E2 COPY ANALYSIS TO SCOTT LADD ALSO
SC904-021-01 0100 EZ ERROR CODE WOULDN’T ZERO   Y AXIS FLASHING E2 NTC WAS UNSOLDER TO THE POWER BOARD. SOLDERED NTC. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 5199 RESOLVER FEEDBACK ISSUE INTERMITTENT DURING CYCLE FOR HOURS U10 DEFECTIVE ON POWER BOARD. REPLACED U10. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 5199 UNABLE TO DRIVE THE X2 AXIS INCORRECT MOTOR OUTPUT OUT OF AMP 3.J2  FAILED AFTER 16HRS OF CYCLE U9 DEFECTIVE ON POWER BOARD. REPLACED U9. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 5199 CAUSES HEAD TO RUN AWAY NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4999 NOISY AXIS X  RESOVER ISSUE NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 3599 CAUSES OSCILLATION IN HEAD MOTOR THIS WAS ALREADY REC’D ON RMA 122882 BEMILL 1-04-00
SC903NN-031-01 4399 COMMUNICATION PROBLEM IN AMPLIFIER U12 DEFECTIVE ON POWER BOARD. REPLACED U12. UNIT PASSED BURN-IN AND FINAL TEST.
SC902-028-01 3599 CAUSES OSCILLATION IN HEAD MOTOR NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 4599 FLASHING E ON DISPLAY NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST. NO CHARGE.
SC903-020-01 3598 CONTROL BOARD NEEDS CALIBRATION. RE-CALIBRATED CONTROL BOARD. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 2199 R260 DEFECTIVE ON CONTROL BOARD. REPLACED R260. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 3099 C302 FAILED [SHORTED]. REPLACED C302. UNIT PASSED BURN-IN AND FINAL TEST.
SC904-021-01 4599 FLASHING E AT START UP NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST. NO CHARGE.
SC904-021-01 4499 CAUSES A VELOCITY OVERSPEED ERROR INTERMITTENT
SC903-020-01 3099 DRIVE OVERTEMP ERROR AFTER 1 MONTH OPERATION ON TEST MACHINE. FLASHING 3 NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST. NO CHARGE.
SC904-021-01 4599 FLASHING E, POWER UP SELF TEST FAIL NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST. NO CHARGE.
SC903-020-01 9701 CUSTOMER ISSUE: REGEN MELTED, PTC MELTED AND F1 AND F2 OPEN DUE TO EXCESSIVE REGENERATION BY CUSTOMER. WAITING FOR CUSTOMER’S FOR APPROVAL OF MINOR REPAIR. CUSTOMER WANTS UNIT RETURN UNREPAIR.
SC903-020-01 4398 EXCESSIVE REGEN WAS APPLIED, CAUSED REGEN RESISTOR BURNT AND F1/F2 FUSE BLOWN. J4 AND PIN 14 DAMAGED BY CUSTOMER. PLEASE VERIFY CUSTOMER FOR APPROVAL A MINOR REPAIR CHARGE. CUSTOMER WANTS UNIT RETURN UNREPAIR.
SC903-020-01 4198 HOT SMELL, RUSH NEED ANALYSIS ASAP CUSTOMER ISSUE: EXCESSIVE REGENERATION CAUSED REGEN RESISTOR TO BURN AND F1 AND F2 TO OPEN. WAITING FOR CUSTOMER’S APPROVAL OF MINOR REPAIR. CUSTOMER WANTS UNIT RETURN UNREPAIR.
SC902-028-01 3099 ONE STANDOFF MISSING, THE OTHER IS LOOSE MISSING HEX SCREW ON J4 OF THE CONTROL BOARD. ADDED 1 HEX SCREW AND TIGHTEN BOTH SCREWS. UNIT PASSED BURN-IN AND FINAL TEST.
SC903-020-01 4399 FLASHING 7- OUTPUT OVERCURRENT OR VUS VOLTAGE NO PROBLEM FOUND. UNIT PASSED BURN-IN AND FINAL TEST.